High throughputs
The extrex HV with 25% higher specific pumping volume, made possible by its special design, is recommended for standard applications - i.e. polymers that are not very or moderate temperature-sensitive and applications involving frequent colour and product changes.
Benefits
Longer gears permit a 25% higher specific pumping volume.
Design features:
- No dead zones
- Optimised flow inlet and oulet channels
- Optional temperature control thanks to heating medium
- Coolable shaft seals for low-viscosity polymers
- Interface-compatible with most 3rd and 4th generation Maag pumps and the extrex GP
Application limits
Outlet pressure [bar]: | Up to max. 300 |
Differential pressure [bar]: | Up to max. 200 |
Pump size: | 45 to 90 |
Specific volume [cm3/rev]: | 57.6 to 453 |
Throughput range [kg/h]: | |
Viscosity [Pas]: | Up to 30,000 |
Temperature [°C]: | Up to 350 |